![Master industrial heating web](https://dantherm-group-cdn.s3.amazonaws.com/cache/media/featured-images/75418/Master-industrial-heating-web_62dda3d0eca755a65e281f4618812b96.webp)
High volumes of heat right where you need it and at low cost
![Katarzyna Cellary Zinko](https://dantherm-group-cdn.s3.amazonaws.com/cache/media/29303/Katarzyna-Cellary-Zinko_9a22d6bc7444ca578ca16cbaadf32b40.webp)
SF/HP are fixed, high-performance forced-air furnaces fitted with indirect-fired oil or gas burners. Specially designed for the needs of industry, they are fitted with high flow rate and high discharge pressure fans, and are available in a wide range of versions. SF/HP units are particularly well suited to heating and ventilation of industrial processes, hot air compensation in rooms with air extraction, surface treatment buildings, drying rooms, paint booths, and heating with distribution via a network of highly constrained ducts.
Specifications | Units | SF 136 - HP 1 |
---|---|---|
Type |
|
HP 1
|
Heating power |
kW
|
150
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 4
|
Max. fuel consumption |
kg/h
|
12.7
|
Max. propane gas (G31) |
kg/h
|
10.7
|
Max. natural gas (G20) |
m³/h
|
14.3
|
Air flow |
m³/h
|
15,000
|
Air pressure |
Pa
|
150
|
Temperature increase (DT) |
°C
|
15-26
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
740
|
Specifications | Units | SF 136 - HP 2 |
---|---|---|
Type |
|
HP 2
|
Heating power |
kW
|
150
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 5.5
|
Max. fuel consumption |
kg/h
|
12.7
|
Max. propane gas (G31) |
kg/h
|
10.7
|
Max. natural gas (G20) |
m³/h
|
14.3
|
Air flow |
m³/h
|
19,000
|
Air pressure |
Pa
|
200
|
Temperature increase (DT) |
°C
|
15-20.6
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
750
|
Specifications | Units | SF 236 - HP 1 |
---|---|---|
Type |
|
HP 1
|
Heating power |
kW
|
260
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 4
|
Max. fuel consumption |
kg/h
|
21.9
|
Max. propane gas (G31) |
kg/h
|
18.6
|
Max. natural gas (G20) |
m³/h
|
24.8
|
Air flow |
m³/h
|
16,000
|
Air pressure |
Pa
|
150
|
Temperature increase (DT) |
°C
|
21.2-42.3
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
760
|
Specifications | Units | SF 236 - HP 2 |
---|---|---|
Type |
|
HP 2
|
Heating power |
kW
|
260
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 5.5
|
Max. fuel consumption |
kg/h
|
21.9
|
Max. propane gas (G31) |
kg/h
|
18.6
|
Max. natural gas (G20) |
m³/h
|
24.8
|
Air flow |
m³/h
|
20,000
|
Air pressure |
Pa
|
200
|
Temperature increase (DT) |
°C
|
17-33.9
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
775
|
Specifications | Units | SF 236 - HP 3 |
---|---|---|
Type |
|
HP 3
|
Heating power |
kW
|
260
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 7.5
|
Max. fuel consumption |
kg/h
|
21.9
|
Max. propane gas (G31) |
kg/h
|
18.6
|
Max. natural gas (G20) |
m³/h
|
24.8
|
Air flow |
m³/h
|
24,000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
15-28.3
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
772
|
Specifications | Units | SF 236 - HP 4 |
---|---|---|
Type |
|
HP 4
|
Heating power |
kW
|
260
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 9.2
|
Max. fuel consumption |
kg/h
|
21.9
|
Max. propane gas (G31) |
kg/h
|
18.6
|
Max. natural gas (G20) |
m³/h
|
24.8
|
Air flow |
m³/h
|
26,000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
15-26.1
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
810
|
Specifications | Units | SF 236 - HP 5 |
---|---|---|
Type |
|
HP 5
|
Heating power |
kW
|
260
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
1 x 11
|
Max. fuel consumption |
kg/h
|
21,9
|
Max. propane gas (G31) |
kg/h
|
18,6
|
Max. natural gas (G20) |
m³/h
|
24,8
|
Air flow |
m³/h
|
29.000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
17,6 - 23,4
|
Product size (l x w x h) |
mm
|
1500 x 1200 x 3410
|
Weight |
kg
|
820
|
Specifications | Units | SF 342 - HP 1 |
---|---|---|
Type |
|
HP 1
|
Heating power |
kW
|
380
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
2 x 4
|
Max. fuel consumption |
kg/h
|
32.1
|
Max. propane gas (G31) |
kg/h
|
27.1
|
Max. natural gas (G20) |
m³/h
|
36.2
|
Air flow |
m³/h
|
32,000
|
Air pressure |
Pa
|
150
|
Temperature increase (DT) |
°C
|
15.3-30.6
|
Product size (l x w x h) |
mm
|
2400 x 2250 x 3410
|
Weight |
kg
|
1,130
|
Specifications | Units | SF 342 - HP 2 |
---|---|---|
Type |
|
HP 2
|
Heating power |
kW
|
380
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
2 x 5.5
|
Max. fuel consumption |
kg/h
|
32.1
|
Max. propane gas (G31) |
kg/h
|
27.1
|
Max. natural gas (G20) |
m³/h
|
36.2
|
Air flow |
m³/h
|
40,000
|
Air pressure |
Pa
|
200
|
Temperature increase (DT) |
°C
|
15-24.5
|
Product size (l x w x h) |
mm
|
2400 x 2250 x 3410
|
Weight |
kg
|
1,160
|
Specifications | Units | SF 342 - HP 3 |
---|---|---|
Type |
|
HP 3
|
Heating power |
kW
|
380
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
2 x 7.5
|
Max. fuel consumption |
kg/h
|
32.1
|
Max. propane gas (G31) |
kg/h
|
27.1
|
Max. natural gas (G20) |
m³/h
|
36.2
|
Air flow |
m³/h
|
48,000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
15-20.4
|
Product size (l x w x h) |
mm
|
2400 x 2250 x 3410
|
Weight |
kg
|
1,154
|
Specifications | Units | SF 342 - HP 4 |
---|---|---|
Type |
|
HP 4
|
Heating power |
kW
|
380
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
2 x 9.2
|
Max. fuel consumption |
kg/h
|
32.1
|
Max. propane gas (G31) |
kg/h
|
27.1
|
Max. natural gas (G20) |
m³/h
|
36.2
|
Air flow |
m³/h
|
52,000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
15-18.9
|
Product size (l x w x h) |
mm
|
2400 x 2250 x 3410
|
Weight |
kg
|
1,230
|
Specifications | Units | SF 342 - HP 5 |
---|---|---|
Type |
|
HP 5
|
Heating power |
kW
|
380
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
2 x 11
|
Max. fuel consumption |
kg/h
|
32.1
|
Max. propane gas (G31) |
kg/h
|
27.1
|
Max. natural gas (G20) |
m³/h
|
36.2
|
Air flow |
m³/h
|
58,000
|
Air pressure |
Pa
|
250
|
Temperature increase (DT) |
°C
|
15-16.9
|
Product size (l x w x h) |
mm
|
2400 x 2250 x 3410
|
Weight |
kg
|
1,250
|
Specifications | Units | SF 495 - HP 1 |
---|---|---|
Type |
|
HP 1
|
Heating power |
kW
|
550
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
3 x 4
|
Max. fuel consumption |
kg/h
|
46.4
|
Max. propane gas (G31) |
kg/h
|
39.3
|
Max. natural gas (G20) |
m³/h
|
52.4
|
Air flow |
m³/h
|
48,000
|
Air pressure |
Pa
|
150
|
Temperature increase (DT) |
°C
|
15-29.6
|
Product size (l x w x h) |
mm
|
3600 x 2250 x 3470
|
Weight |
kg
|
1,930
|
Specifications | Units | SF 495 - HP 2 |
---|---|---|
Type |
|
HP 2
|
Heating power |
kW
|
550
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
3 x 5.5
|
Max. fuel consumption |
kg/h
|
46.4
|
Max. propane gas (G31) |
kg/h
|
39.3
|
Max. natural gas (G20) |
m³/h
|
52.4
|
Air flow |
m³/h
|
60,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-23.7
|
Product size (l x w x h) |
mm
|
3600 x 2250 x 3470
|
Weight |
kg
|
1,975
|
Specifications | Units | SF 495 - HP 3 |
---|---|---|
Type |
|
HP 3
|
Heating power |
kW
|
550
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
3 x 7.5
|
Max. fuel consumption |
kg/h
|
46.4
|
Max. propane gas (G31) |
kg/h
|
39.3
|
Max. natural gas (G20) |
m³/h
|
52.4
|
Air flow |
m³/h
|
72,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-19.7
|
Product size (l x w x h) |
mm
|
3600 x 2250 x 3470
|
Weight |
kg
|
1,966
|
Specifications | Units | SF 495 - HP 4 |
---|---|---|
Type |
|
HP 4
|
Heating power |
kW
|
550
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
3 x 9.2
|
Max. fuel consumption |
kg/h
|
46.4
|
Max. propane gas (G31) |
kg/h
|
39.3
|
Max. natural gas (G20) |
m³/h
|
52.4
|
Air flow |
m³/h
|
78,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-18.2
|
Product size (l x w x h) |
mm
|
3600 x 2250 x 3470
|
Weight |
kg
|
2,080
|
Specifications | Units | SF 630 - HP 1 |
---|---|---|
Type |
|
HP 1
|
Heating power |
kW
|
700
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
4 x 4
|
Max. fuel consumption |
kg/h
|
59.1
|
Max. propane gas (G31) |
kg/h
|
50
|
Max. natural gas (G20) |
m³/h
|
66.7
|
Air flow |
m³/h
|
64,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-28.2
|
Product size (l x w x h) |
mm
|
4800 x 2250 x 3470
|
Weight |
kg
|
2,540
|
Specifications | Units | SF 630 - HP 2 |
---|---|---|
Type |
|
HP 2
|
Heating power |
kW
|
700
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
4 x 5.5
|
Max. fuel consumption |
kg/h
|
59.1
|
Max. propane gas (G31) |
kg/h
|
50
|
Max. natural gas (G20) |
m³/h
|
66.7
|
Air flow |
m³/h
|
80,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-22.6
|
Product size (l x w x h) |
mm
|
4800 x 2250 x 3470
|
Weight |
kg
|
2,600
|
Specifications | Units | SF 630 - HP 3 |
---|---|---|
Type |
|
HP 3
|
Heating power |
kW
|
700
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
4 x 7.5
|
Max. fuel consumption |
kg/h
|
59.1
|
Max. propane gas (G31) |
kg/h
|
50
|
Max. natural gas (G20) |
m³/h
|
66.7
|
Air flow |
m³/h
|
96,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-18.8
|
Product size (l x w x h) |
mm
|
4800 x 2250 x 3470
|
Weight |
kg
|
2,588
|
Specifications | Units | SF 630 - HP 4 |
---|---|---|
Type |
|
HP 4
|
Heating power |
kW
|
700
|
Electric power |
Type
|
380
|
No. of fans x fan power |
No. x kW
|
4 x 9.2
|
Max. fuel consumption |
kg/h
|
59.1
|
Max. propane gas (G31) |
kg/h
|
50
|
Max. natural gas (G20) |
m³/h
|
66.7
|
Air flow |
m³/h
|
104,000
|
Air pressure |
Pa
|
100
|
Temperature increase (DT) |
°C
|
15-17.4
|
Product size (l x w x h) |
mm
|
4800 x 2250 x 3470
|
Weight |
kg
|
2,740
|
Get in touch and we will connect you with the right office or dealer.
The direct route to spare parts for your equipment.
Contact us for help in finding the right service professional near you.
High volumes of heat right where you need it and at low cost
What you need to know before making your decision
Keeping warehouses and industrial buildings at the right temperature is crucial for your people, products and processes. Learn how to warm these spaces efficiently and capably with the ideal portable heater.
Complete your details below and the right person from our expert team will get back to you.
For service and spare parts enquiries please include serial number and product type in the Message field.
Thank you for your enquiry. We will be in touch with you as soon as possible.