Dantherm Group
Master

Master SF range – indirect oil-fired heaters

Models: SF 70-95-130-190-260-360-500-600-700-900-1200

The SF series are vertical or horizontal indirect-fired heaters. They can be supplied with or without oil, propane or natural gas burners.

They are designed to provide fast, efficient and economical heating for volumes or assemblies of up to 35,000m³.

They are particularly well suited to heating industrial, agricultural or public buildings, workshops or garages, warehouses, shops, reception or exhibition halls, and sports halls.

View all of our indirect oil fired air heaters and other types of portable commercial heaters to meet your required applications.

SF indirect oil fired heater
SF indirect oil fired heater
SF indirect oil fired heater side view
SF indirect oil fired heater side view
Sovelor SF horizontal
Sovelor SF horizontal
Sovelor SF factory installation
Sovelor SF factory installation

Key features

  • Vertical or horizontal monoblocks
  • Supplied with or without oil, propane or natural gas burner
  • High-pressure centrifugal fan with double intake
  • High air flow
  • 2mm thick combustion chamber with flame return
  • Reinforced chamber bottom in refractory stainless steel
  • Heat exchanger with stainless steel flue gas turbulators
  • 10/10mm thick pre-painted galvanised sheet metal casing
  • Panel thermal insulation
  • Integrated watertight electrical panel
  • Inspection hatches for easy maintenance of the firebox/exchanger assembly and flue gas manifold
  • Bi-thermostat "fan-limit" doubled with an independent overheating thermostat
  • Can run on HVO100 biofuel, diesel or kerosene

High performance

Whether used for direct air discharge (directional heads) or connected to a duct network, SF units offer first-class performance: power ratings ranging from 60.7 to 1,160 kW, efficiencies of over 90% across the range, and air flow rates of between 4,300 and 72,000 m³/h.
These features give them a particularly favourable cost/efficiency ratio.

Rational

Simple to install, SF generators produce immediately available heat for a moderate investment in relation to the volume heated. Thanks to their high-pressure centrifugal fan, they can heat several rooms with a single generator via a network of ducts. Their high airflow rate means that temperatures rise quickly, making it unnecessary to keep the generator running when the room is unoccupied. The exceptional efficiency of SF series heaters (over 90%) is a guarantee of efficiency and energy savings.

Quality

SF heaters are top-of-the-range appliances, with everything in their design and construction designed for maximum efficiency and reliability:

  • 2 mm thick combustion chamber with flame return
  • Refractory stainless steel reinforced chamber bottom
  • Heat exchanger with stainless steel flue gas turbulators (firebox guaranteed for 5 years)
  • High-pressure centrifugal fan with double intake
  • Complete chassis in galvanised sheet metal
  • Body in 10/10 mm thick pre-painted electro-galvanised sheet metal
  • Thermal insulation of panels
  • Integrated watertight electrical panel
  • Inspection hatches for easy maintenance of the firebox/exchanger assembly and flue gas manifold
  • Bi-thermostat "fan-limit" doubled with an independent overheating thermostat

Product specifications

SpecificationsUnitsSF 70
Heating power
kW
60.7
Air flow
m³/h
4,300
Air pressure
Pa
100
Fuel consumption
kg/h
5.1
Natural gas (G20)
m³/h
6.4
Propane gas (G31)
kg/h
4.7
Power supply
V/Hz
230/1ph/50
Electric power
W
740
Noise level at 1.5 m
dB(A)
65
Fan
pcs
1
Air blast range
m
17
SpecificationsUnitsSF 95
Heating power
kW
92
Air flow
m³/h
5,800
Air pressure
Pa
160
Fuel consumption
kg/h
7.7
Natural gas (G20)
m³/h
9.7
Propane gas (G31)
kg/h
7.2
Power supply
V/Hz
380/3ph/50
Electric power
W
1,100
Noise level at 1.5 m
dB(A)
66
Fan
pcs
1
Air blast range
m
20
SpecificationsUnitsSF 130
Heating power
kW
115.9
Air flow
m³/h
7,800
Air pressure
Pa
180
Fuel consumption
kg/h
9.8
Natural gas (G20)
m³/h
12.3
Propane gas (G31)
kg/h
9
Power supply
V/Hz
380/3ph/50
Electric power
W
1,500
Noise level at 1.5 m
dB(A)
67
Fan
pcs
1
Air blast range
m
24
SpecificationsUnitsSF 190
Heating power
kW
185.8
Air flow
m³/h
11,100
Air pressure
Pa
200
Fuel consumption
kg/h
15.6
Natural gas (G20)
m³/h
19.6
Propane gas (G31)
kg/h
14.5
Power supply
V/Hz
380/3ph/50
Electric power
W
3,000
Noise level at 1.5 m
dB(A)
71
Fan
pcs
1
Air blast range
m
35
SpecificationsUnitsSF 260
Heating power
kW
232.6
Air flow
m³/h
15,000
Air pressure
Pa
200
Fuel consumption
kg/h
19.6
Natural gas (G20)
m³/h
24.6
Propane gas (G31)
kg/h
18.1
Power supply
V/Hz
380/3ph/50
Electric power
W
4,000
Noise level at 1.5 m
dB(A)
73
Fan
pcs
1
Air blast range
m
50
SpecificationsUnitsSF 360
Heating power
kW
348.8
Air flow
m³/h
20,250
Air pressure
Pa
180
Fuel consumption
kg/h
29.4
Natural gas (G20)
m³/h
36.8
Propane gas (G31)
kg/h
27.2
Power supply
V/Hz
380/3ph/50
Electric power
W
2 x 3,000
Noise level at 1.5 m
dB(A)
73
Fan
pcs
2
Air blast range
m
65
SpecificationsUnitsSF 500
Heating power
kW
465.1
Air flow
m³/h
31,000
Air pressure
Pa
240
Fuel consumption
kg/h
39.2
Natural gas (G20)
m³/h
49.1
Propane gas (G31)
kg/h
36.3
Power supply
V/Hz
380/3ph/50
Electric power
W
2 x 4,000
Noise level at 1.5 m
dB(A)
73
Fan
pcs
2
Air blast range
m
75
SpecificationsUnitsSF 600
Heating power
kW
581.4
Air flow
m³/h
35,000
Air pressure
Pa
200
Fuel consumption
kg/h
49
Natural gas (G20)
m³/h
61.4
Propane gas (G31)
kg/h
45.4
Power supply
V/Hz
380/3ph/50
Electric power
W
2 x 4,000
Noise level at 1.5 m
dB(A)
73
Fan
pcs
2
Air blast range
m
80
SpecificationsUnitsSF 700
Heating power
kW
697.7
Air flow
m³/h
43,500
Air pressure
Pa
200
Fuel consumption
kg/h
58.8
Natural gas (G20)
m³/h
73.7
Propane gas (G31)
kg/h
54.5
Power supply
V/Hz
380/3ph/50
Electric power
W
2 x 5,500
Noise level at 1.5 m
dB(A)
74
Fan
pcs
2
Air blast range
m
87
SpecificationsUnitsSF 900
Heating power
kW
872
Air flow
m³/h
53,000
Air pressure
Pa
180
Fuel consumption
kg/h
73.5
Natural gas (G20)
m³/h
92.1
Propane gas (G31)
kg/h
68.1
Power supply
V/Hz
380/3ph/50
Electric power
W
2 x 7,500
Noise level at 1.5 m
dB(A)
74
Fan
pcs
2
Air blast range
m
95
SpecificationsUnitsSF 1200
Heating power
kW
1,163
Air flow
m³/h
72,000
Air pressure
Pa
200
Fuel consumption
kg/h
98
Natural gas (G20)
m³/h
122.9
Propane gas (G31)
kg/h
90.8
Power supply
V/Hz
380/3ph/50
Electric power
W
3 x 7,500
Noise level at 1.5 m
dB(A)
70
Fan
pcs
3
Air blast range
m
110

Suitable for

  • Commercial buildings
  • Industrial, factories and production
  • Leisure and recreation
  • Swimming pools
  • Transport and logistics