The I-PAC PRO range is the next generation of high-performance inverter heat pumps that are designed specifically for energy-efficient heating and cooling of swimming pools. Engineered with cutting-edge technology and eco-friendly components, the heat pumps offer a reliable and energy-efficient solution for a wide range of pool applications, including outdoor and indoor pools, hotel and spa pools, therapy pools, health clubs, and wellness centers.
The units combine advanced features with user-friendly controls, making them an ideal choice for both commercial and private settings. With their quiet operation, robust performance, and remote monitoring capabilities, they provide unparalleled convenience, performance, and comfort all year round.
![]()
I-PAC PRO 10A
| ![]()
I-PAC PRO 16A
|
![]()
I-PAC PRO video
| ![]()
I-PAC PRO 22A/22B
|
![]()
I-PAC PRO 28A/28B
| ![]()
I-PAC PRO 36A/36B
|
Key features
- Inverter heat pumps – deliver enhanced performance and energy savings
- Expanded range – includes high-capacity single- and three-phase models (I-PAC PRO 28A and 36B)
- Eco-friendly R32 refrigerant – environmentally responsible and highly efficient
- Titanium condenser – provides corrosion resistance and durability in pool environments
- Touchscreen user interface – integrated controller with real-time data and easy operation
- Multi-function operation – choose from heating, cooling, or a combination of both
- Built-in Wi-Fi module – control your heat pump remotely via the Pooltherm App
- Operating range of -20°C to +43°C – reliable yearround operation in extreme temperatures
- New silence mode – reduces noise levels, perfect for noise-sensitive locations
- Standard supply – winter cover, anti-vibration mounts, condensate drainage kit and water union connectors
- Optional – wired remote control panel with 10m cable
- The minimum security update period for I-PAC PRO products is zero months
- The minimum security update period for the PoolTherm App aligns with the warranty period of the connected product (5 years from the date of sale of the connected I-PAC PRO heat pump)
Product specifications
Specifications | Units | I-PAC PRO 10A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 14.5 |
Heating capacity (Perfect mode) | kw | 11.6 |
COP range (Perfect mode) | 7.5 ~ 20.1 | |
COP 50% speed (Perfect mode) | 14.8 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 9.6 |
Heating capacity (Perfect mode) | kw | 7.8 |
COP range (Perfect mode) | 5.2 ~ 8.6 | |
COP 50% speed (Perfect mode) | 7.4 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 9.3 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 5.2 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 6.7 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kw | 0.22 ~ 1.85 |
Max input current | A | 12.5 |
Waterflow | m³/h | 3 ~ 4 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 1.25 / 0.844 | |
Sound level @10m | dB(A) | 16.4 ~ 24.8 |
Dimensions (w x d x h) | mm | 946 x 427 x 660 |
Net weight | kg | 65 |
Specifications | Units | I-PAC PRO 16A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 22.5 |
Heating capacity (Perfect mode) | kw | 18 |
COP range (Perfect mode) | 7.3 ~ 20.4 | |
COP 50% speed (Perfect mode) | 15.2 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 15 |
Heating capacity (Perfect mode) | kw | 12 |
COP range (Perfect mode) | 5.3 ~ 9.0 | |
COP 50% speed (Perfect mode) | 7.7 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 14.9 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 8.2 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 11.9 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kw | 0.34 ~ 2.83 |
Max input current | A | 18.5 |
Waterflow | m³/h | 6 ~ 9 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 1.7 / 1.148 | |
Sound level @10m | dB(A) | 18.8 ~ 28.5 |
Dimensions (w x d x h) | mm | 1195 x 427 x 760 |
Net weight | kg | 82 |
Specifications | Units | I-PAC PRO 22A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 27 |
Heating capacity (Perfect mode) | kw | 21.6 |
COP range (Perfect mode) | 7.4 ~ 20.2 | |
COP 50% speed (Perfect mode) | 15 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 18.5 |
Heating capacity (Perfect mode) | kw | 15 |
COP range (Perfect mode) | 5.2 ~ 8.9 | |
COP 50% speed (Perfect mode) | 7.6 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 17.5 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 10.3 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 13.5 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kw | 0.43 ~ 3.56 |
Max input current | A | 20.5 |
Waterflow | m³/h | 8 ~ 10 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 2.3 / 1.553 | |
Sound level @10m | dB(A) | 18.8 ~ 29.2 |
Dimensions (w x d x h) | mm | 1071 x 536 x 953 |
Net weight | kg | 100 |
Specifications | Units | I-PAC PRO 22B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 27 |
Heating capacity (Perfect mode) | kw | 21.6 |
COP range (Perfect mode) | 7.3 ~ 20.1 | |
COP 50% speed (Perfect mode) | 14.9 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 18.5 |
Heating capacity (Perfect mode) | kw | 15 |
COP range (Perfect mode) | 5.3 ~ 8.6 | |
COP 50% speed (Perfect mode) | 7.4 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 17.2 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 9.9 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 13.5 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kw | 0.42 ~ 3.49 |
Max input current | A | 8 |
Waterflow | m³/h | 8 ~ 10 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 2.4 / 1.62 | |
Sound level @10m | dB(A) | 19.0 ~ 29.4 |
Dimensions (w x d x h) | mm | 1071 x 536 x 953 |
Net weight | kg | 111 |
Specifications | Units | I-PAC PRO 28A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 32.5 |
Heating capacity (Perfect mode) | kw | 26 |
COP range (Perfect mode) | 7.2 ~ 20 | |
COP 50% speed (Perfect mode) | 14.7 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 22.7 |
Heating capacity (Perfect mode) | kw | 18.8 |
COP range (Perfect mode) | 5.4 ~ 8.1 | |
COP 50% speed (Perfect mode) | 7.2 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 21.4 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 11.4 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 15.4 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kw | 0.50 ~ 4.20 |
Max input current | A | 24 |
Waterflow | m³/h | 10 ~ 12 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 3 / 2.025 | |
Sound level @10m | dB(A) | 19.6 ~ 30.2 |
Dimensions (w x d x h) | mm | 1264 x 536 x 954 |
Net weight | kg | 122 |
Specifications | Units | I-PAC PRO 28B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 32.5 |
Heating capacity (Perfect mode) | kw | 26 |
COP range (Perfect mode) | 7.3 ~ 19.7 | |
COP 50% speed (Perfect mode) | 14.6 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 22.7 |
Heating capacity (Perfect mode) | kw | 18.8 |
COP range (Perfect mode) | 5.3 ~ 8.2 | |
COP 50% speed (Perfect mode) | 7.2 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 21.6 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 11.6 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 15.4 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kw | 0.51 ~ 4.28 |
Max input current | A | 9.4 |
Waterflow | m³/h | 10 ~ 12 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 3 / 2.025 | |
Sound level @10m | dB(A) | 19.7 ~ 30.4 |
Dimensions (w x d x h) | mm | 1264 x 536 x 954 |
Net weight | kg | 132 |
Specifications | Units | I-PAC PRO 36B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) | kw | 40.5 |
Heating capacity (Perfect mode) | kw | 32.5 |
COP range (Perfect mode) | 7.3 ~ 20 | |
COP 50% speed (Perfect mode) | 14.7 | |
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) | kw | 29 |
Heating capacity (Perfect mode) | kw | 23.5 |
COP range (Perfect mode) | 5.2 ~ 8.0 | |
COP 50% speed (Perfect mode) | 7.1 | |
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) | kw | 27.5 |
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) | kw | 14.9 |
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy | kw | 20 |
General specifications | ||
Air temperature range | °C | -20°C to 43°C |
Water heating setting range | °C | 18°C to 40°C |
Water cooling setting range | °C | 5°C to 30°C |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kw | 0.67 ~ 5.58 |
Max input current | A | 12.5 |
Waterflow | m³/h | 12 ~ 18 |
Water connection | mm | 48.3 or 50 Female |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight / CO2 equivalent | 3.6 / 2.43 | |
Sound level @10m | dB(A) | 19.9 ~ 30.5 |
Dimensions (w x d x h) | mm | 1364 x 536 x 954 |
Net weight | kg | 147 |
Suitable for
- Leisure and recreation