The I-PAC PRO range is the next generation of high-performance inverter heat pumps that are designed specifically for energy-efficient heating and cooling of swimming pools. Engineered with cutting-edge technology and eco-friendly components, the heat pumps offer a reliable and energy-efficient solution for a wide range of pool applications, including outdoor and indoor pools, hotel and spa pools, therapy pools, health clubs, and wellness centers.
The units combine advanced features with user-friendly controls, making them an ideal choice for both commercial and private settings. With their quiet operation, robust performance, and remote monitoring capabilities, they provide unparalleled convenience, performance, and comfort all year round.
Specifications | Units | I-PAC PRO 10A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
14.5
|
Heating capacity (Perfect mode) |
kw
|
11.6
|
COP range (Perfect mode) |
|
7.5 ~ 20.1
|
COP 50% speed (Perfect mode) |
|
14.8
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
9.6
|
Heating capacity (Perfect mode) |
kw
|
7.8
|
COP range (Perfect mode) |
|
5.2 ~ 8.6
|
COP 50% speed (Perfect mode) |
|
7.4
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
9.3
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
5.2
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
6.7
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kw
|
0.22 ~ 1.85
|
Max input current |
A
|
12.5
|
Waterflow |
m³/h
|
3 ~ 4
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
1.25 / 0.844
|
Sound level @10m |
dB(A)
|
16.4 ~ 24.8
|
Dimensions (w x d x h) |
mm
|
946 x 427 x 660
|
Net weight |
kg
|
65
|
Specifications | Units | I-PAC PRO 16A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
22.5
|
Heating capacity (Perfect mode) |
kw
|
18
|
COP range (Perfect mode) |
|
7.3 ~ 20.4
|
COP 50% speed (Perfect mode) |
|
15.2
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
15
|
Heating capacity (Perfect mode) |
kw
|
12
|
COP range (Perfect mode) |
|
5.3 ~ 9.0
|
COP 50% speed (Perfect mode) |
|
7.7
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
14.9
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
8.2
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
11.9
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kw
|
0.34 ~ 2.83
|
Max input current |
A
|
18.5
|
Waterflow |
m³/h
|
6 ~ 9
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
1.7 / 1.148
|
Sound level @10m |
dB(A)
|
18.8 ~ 28.5
|
Dimensions (w x d x h) |
mm
|
1195 x 427 x 760
|
Net weight |
kg
|
82
|
Specifications | Units | I-PAC PRO 22A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
27
|
Heating capacity (Perfect mode) |
kw
|
21.6
|
COP range (Perfect mode) |
|
7.4 ~ 20.2
|
COP 50% speed (Perfect mode) |
|
15
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
18.5
|
Heating capacity (Perfect mode) |
kw
|
15
|
COP range (Perfect mode) |
|
5.2 ~ 8.9
|
COP 50% speed (Perfect mode) |
|
7.6
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
17.5
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
10.3
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
13.5
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kw
|
0.43 ~ 3.56
|
Max input current |
A
|
20.5
|
Waterflow |
m³/h
|
8 ~ 10
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
2.3 / 1.553
|
Sound level @10m |
dB(A)
|
18.8 ~ 29.2
|
Dimensions (w x d x h) |
mm
|
1071 x 536 x 953
|
Net weight |
kg
|
100
|
Specifications | Units | I-PAC PRO 22B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
27
|
Heating capacity (Perfect mode) |
kw
|
21.6
|
COP range (Perfect mode) |
|
7.3 ~ 20.1
|
COP 50% speed (Perfect mode) |
|
14.9
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
18.5
|
Heating capacity (Perfect mode) |
kw
|
15
|
COP range (Perfect mode) |
|
5.3 ~ 8.6
|
COP 50% speed (Perfect mode) |
|
7.4
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
17.2
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
9.9
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
13.5
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
400/3ph/50
|
Rated input power |
kw
|
0.42 ~ 3.49
|
Max input current |
A
|
8
|
Waterflow |
m³/h
|
8 ~ 10
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
2.4 / 1.62
|
Sound level @10m |
dB(A)
|
19.0 ~ 29.4
|
Dimensions (w x d x h) |
mm
|
1071 x 536 x 953
|
Net weight |
kg
|
111
|
Specifications | Units | I-PAC PRO 28A |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
32.5
|
Heating capacity (Perfect mode) |
kw
|
26
|
COP range (Perfect mode) |
|
7.2 ~ 20
|
COP 50% speed (Perfect mode) |
|
14.7
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
22.7
|
Heating capacity (Perfect mode) |
kw
|
18.8
|
COP range (Perfect mode) |
|
5.4 ~ 8.1
|
COP 50% speed (Perfect mode) |
|
7.2
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
21.4
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
11.4
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
15.4
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
230/1ph/50
|
Rated input power |
kw
|
0.50 ~ 4.20
|
Max input current |
A
|
24
|
Waterflow |
m³/h
|
10 ~ 12
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
3 / 2.025
|
Sound level @10m |
dB(A)
|
19.6 ~ 30.2
|
Dimensions (w x d x h) |
mm
|
1264 x 536 x 954
|
Net weight |
kg
|
122
|
Specifications | Units | I-PAC PRO 28B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
32.5
|
Heating capacity (Perfect mode) |
kw
|
26
|
COP range (Perfect mode) |
|
7.3 ~ 19.7
|
COP 50% speed (Perfect mode) |
|
14.6
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
22.7
|
Heating capacity (Perfect mode) |
kw
|
18.8
|
COP range (Perfect mode) |
|
5.3 ~ 8.2
|
COP 50% speed (Perfect mode) |
|
7.2
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
21.6
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
11.6
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
15.4
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
400/3ph/50
|
Rated input power |
kw
|
0.51 ~ 4.28
|
Max input current |
A
|
9.4
|
Waterflow |
m³/h
|
10 ~ 12
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
3 / 2.025
|
Sound level @10m |
dB(A)
|
19.7 ~ 30.4
|
Dimensions (w x d x h) |
mm
|
1264 x 536 x 954
|
Net weight |
kg
|
132
|
Specifications | Units | I-PAC PRO 36B |
---|---|---|
Performance conditions: Air 27°C / 80%RH / Water 27°C | ||
Heating capacity (Turbo mode) |
kw
|
40.5
|
Heating capacity (Perfect mode) |
kw
|
32.5
|
COP range (Perfect mode) |
|
7.3 ~ 20
|
COP 50% speed (Perfect mode) |
|
14.7
|
Performance conditions: Air 15°C / 70%RH / Water 26°C | ||
Heating capacity (Turbo mode) |
kw
|
29
|
Heating capacity (Perfect mode) |
kw
|
23.5
|
COP range (Perfect mode) |
|
5.2 ~ 8.0
|
COP 50% speed (Perfect mode) |
|
7.1
|
Performance conditions : Air 5°C / 70%RH / Water 10°C | ||
Heating capacity (Turbo mode) |
kw
|
27.5
|
Performance conditions : Air -10°C / 70%RH / Water 23°C | ||
Heating capacity (Turbo mode) |
kw
|
14.9
|
Performance conditions : Air 35°C / 80%RH / Water 28°C | ||
Cooling capaciy |
kw
|
20
|
General specifications | ||
Air temperature range |
°C
|
-20°C to 43°C
|
Water heating setting range |
°C
|
18°C to 40°C
|
Water cooling setting range |
°C
|
5°C to 30°C
|
Power supply |
V/Hz
|
400/3ph/50
|
Rated input power |
kw
|
0.67 ~ 5.58
|
Max input current |
A
|
12.5
|
Waterflow |
m³/h
|
12 ~ 18
|
Water connection |
mm
|
48.3 or 50 Female
|
Compressor |
|
Inverter
|
Condenser |
|
Titanium
|
R32 gas weight / CO2 equivalent |
|
3.6 / 2.43
|
Sound level @10m |
dB(A)
|
19.9 ~ 30.5
|
Dimensions (w x d x h) |
mm
|
1364 x 536 x 954
|
Net weight |
kg
|
147
|
Get in touch and we will connect you with the right office or dealer.
The direct route to spare parts for your equipment.
Contact us for help in finding the right service professional near you.
Gain valuable insight into what you need to select the right size dehumidifier for your pool.
How to minimise the energy required to heat your swimming pool
Heating an outdoor pool is an energy-consuming process. To keep costs and environmental impact to a minimum, an efficient, sustainable heating solution is essential. Discover how swimming pool heat pumps can unlock significant savings in our article.
Complete your details below and the right person from our expert team will get back to you.
For service and spare parts enquiries please include serial number and product type in the Message field.
Thank you for your enquiry. We will be in touch with you as soon as possible.