Dantherm HCV 300 – residential ventilation unit
Wall-mounted home ventilation units
The HCV 300 is an highly efficient residential ventilation unit for houses, villas, and apartments. It comes as a packaged basic ventilation unit complete with built-in control panel, and is delivered with all parts necessary for wall installation. The HCV 300 is also perfect for concealed installation.
![]()
Dantherm HCV 300 – residential ventilation unit
| ![]()
Dantherm HCV calibration via pc tool
|
![]()
Dantherm HCV calibration using control panel
| ![]()
Dantherm HCV filter timer reset
|
![]()
Dantherm Residential App
|
Key features
- Demand-controlled ventilation with integrated humidity sensor
- Reduced power consumption at times with low ventilation demands
- Summer mode in which supply fan is stopped and any open window will supply cooler outside air, lowering the room temperature
- Fireplace mode, creating a temporary inside overpressure to enhance chimney functionality
- High-efficiency heat recovery
- EC fan motors with extremely low energy consumption (low SPI)
- Easy-to-install and commission solution with built-in air pressure spigots for easy calibration
- Highly customizable units with options to add a high variety of internal as well as external accessories
- HCV 300 models take up less space than a 60 x 60cm cupboard and are perfect for conceled installaton
- Ducts can be connected to the top of the unit, with the option to connect the supply duct to the base if ducts are to run beneath the floor
Product specifications
Specifications | Units | HCV 300 |
---|---|---|
Max. achievable flow at 100Pa | V | m³/h | 280 |
Max. declared flow at 100Pa | V | m³/h | 180 |
Recommended operating range | V | m³/h | 50 - 180 |
EN 13141-7 reference flow | VREF | m³/h | 126 |
Performance | ||
Thermal efficiency in accordance with EN13141-7 | ηSUP | % | 86 |
Specific power consumption in accordance with EN13141-7 | SFP | m³/h | 0.28 |
Leakage (external and internal) in accordance with EN13141-7 | % | <2% (Class A1) |
Filters in accordance with ISO16890 | - | ISO Coarse 75% (optional on supply: ePM1>50% ) |
Filters in accordance with EN779 | - | G4 (optional on supply: F7) |
Installation surrounding temperature | tSURR | °C | +12 to +50 |
Outdoor temperature without preheater installed | tODA | °C | -12 to +50 (The use of the preheating coil is recommended at outdoor temperatures below -3°C to ensure balanced ventilation) |
Outdoor temperature with preheater installed | tODA | °C | -20 to +50 |
Maximum absolute humidity in extract air | x | g/kg | 10 |
Cabinet | ||
Exterior dimensions without wall brackets | w x d x h | mm | 600 x 430 x 1000 |
Spigots/duct connections | Ø | mm | 125 – female |
Weight | kg | 36 |
Heat conductivity – polystyrene insulation | λ | W/mK | 0.031 |
Heat transition figures – polystyrene insulation | U | W/m²K | <1 |
Fire classification of the polystyrene insulation | class | DIN 4102-1 class B2
EN 13501 class E |
Drainage hose | Ø/length | "/mm | ¾ / 1 |
Cabinet colour | RAL | 9016 / galvanized metal grey |
Electrical | ||
Voltage | U | V | 230 |
Maximum power consumption without/with preheater | P | W | 170/870 |
Frequency | f | Hz | 50 |
Protection class | - | IP21 |
Suitable for
- Residential buildings