The Variheat range are sophisticated air handling units incorporating heat pump dehumidification technology. With dynamic heat recovery using a heat pump, the Variheat is the essential choice for a small or medium sized indoor swimming pool as well as commercial use.
With a wide operating range from 35% RH to 100% RH, in air temperatures from 3°C to 35°C, the Variheat air handling unit is the optimum commercial dehumidifier for the majority of humidity control applications. Over 3000 configurations offer the ultimate flexibility for tight plant room spaces. The sophisticated controls, with integral PLC and touchscreen user interface, are ideal for integration with a wide variety of building management systems.
View other swimming pool dehumidifiers or see our full range of commercial and industrial dehumidifiers suitable for multiple applications.
The Variheat range are sophisticated air handling units incorporating heat pump dehumidification technology. With dynamic heat recovery using a heat pump, the Variheat is the essential choice for a domestic or light commercial indoor swimming pool. Over 3000 configurations offer the ultimate flexibility for tight plant room spaces. This range is purposely designed for swimming pool climate control, providing the necessary comfort, moisture related structural protection and economical operation.
Specifications | Units | AW 600 |
---|---|---|
Air flow |
m³/h
|
2,000
|
External available static pressure |
Pa
|
330
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
4.6
|
Dehumidification @ 30°C/70% RH |
l/h
|
5.5
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
5.1
|
Via standard LPHW @ 80°C |
kW
|
11.0
|
Max. available (Mode B + standard LPHW) |
kW
|
14.0
|
Via upgraded LPHW @ 55°C |
kW
|
9.4
|
Max. available (Mode B + upgraded LPHW) |
kW
|
12.7
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
5.5
|
Via LPHW @ 80°C |
kW
|
18.0
|
Max. available (Mode A + LPHW) |
kW
|
23.5
|
Refrigerant |
|
R454C
|
Gas weight/CO2 equivalent |
kg/t
|
1.8/0.26
|
Nominal power consumed |
kW
|
2.1
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AW denotes heat recovery to air/water and LPHW heaters for air/water
|
Specifications | Units | AA 600 |
---|---|---|
Air flow |
m³/h
|
2,000
|
External available static pressure |
Pa
|
330
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
4.6
|
Dehumidification @ 30°C/70% RH |
l/h
|
5.5
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
5.1
|
Via standard LPHW @ 80°C |
kW
|
11.0
|
Max. available (Mode B + standard LPHW) |
kW
|
14.0
|
Via upgraded LPHW @ 55°C |
kW
|
9.4
|
Max. available (Mode B + upgraded LPHW) |
kW
|
12.7
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
0
|
Via LPHW @ 80°C |
kW
|
0
|
Max. available (Mode A + LPHW) |
kW
|
0
|
Refrigerant |
|
R454C
|
Gas weight/CO2 equivalent |
kg/t
|
1.8/0.26
|
Nominal power consumed |
kW
|
2.1
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AA denotes heat recovery to air and optional LPHW heater for air only
|
Specifications | Units | AW 900 |
---|---|---|
Air flow |
m³/h
|
2,500
|
External available static pressure |
Pa
|
220
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
6.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
7.8
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
7.1
|
Via standard LPHW @ 80°C |
kW
|
13.5
|
Max. available (Mode B + standard LPHW) |
kW
|
18.6
|
Via upgraded LPHW @ 55°C |
kW
|
11.5
|
Max. available (Mode B + upgraded LPHW) |
kW
|
16.9
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
7.4
|
Via LPHW @ 80°C |
kW
|
30.0
|
Max. available (Mode A + LPHW) |
kW
|
37.4
|
Refrigerant |
|
R454C
|
Gas weight/CO2 equivalent |
kg/t
|
2.0/0.29
|
Nominal power consumed |
kW
|
2.8
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AW denotes heat recovery to air/water and LPHW heaters for air/water
|
Specifications | Units | AA 900 |
---|---|---|
Air flow |
m³/h
|
2,500
|
External available static pressure |
Pa
|
220
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
6.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
7.8
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
7.1
|
Via standard LPHW @ 80°C |
kW
|
13.5
|
Max. available (Mode B + standard LPHW) |
kW
|
18.6
|
Via upgraded LPHW @ 55°C |
kW
|
11.5
|
Max. available (Mode B + upgraded LPHW) |
kW
|
16.9
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
7.4
|
Via LPHW @ 80°C |
kW
|
30.0
|
Max. available (Mode A + LPHW) |
kW
|
37.4
|
Refrigerant |
|
R454C
|
Gas weight/CO2 equivalent |
kg/t
|
1.85/0.27
|
Nominal power consumed |
kW
|
2.8
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AA denotes heat recovery to air and optional LPHW heater for air only
|
Specifications | Units | AW 1200 |
---|---|---|
Air flow |
m³/h
|
3,500
|
External available static pressure |
Pa
|
290
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
8.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
10.8
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
10.0
|
Via standard LPHW @ 80°C |
kW
|
24.0
|
Max. available (Mode B + standard LPHW) |
kW
|
30.0
|
Via upgraded LPHW @ 55°C |
kW
|
20.4
|
Max. available (Mode B + upgraded LPHW) |
kW
|
27.0
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
10.0
|
Via LPHW @ 80°C |
kW
|
30.0
|
Max. available (Mode A + LPHW) |
kW
|
40.0
|
Refrigerant |
|
R407C
|
Gas weight/CO2 equivalent |
kg/t
|
2.85/5.06
|
Nominal power consumed |
kW
|
3.6
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AW denotes heat recovery to air/water and LPHW heaters for air/water
|
Specifications | Units | AA 1200 |
---|---|---|
Air flow |
m³/h
|
3,500
|
External available static pressure |
Pa
|
290
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
8.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
10.8
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
10.0
|
Via standard LPHW @ 80°C |
kW
|
24.0
|
Max. available (Mode B + standard LPHW) |
kW
|
30.0
|
Via upgraded LPHW @ 55°C |
kW
|
20.4
|
Max. available (Mode B + upgraded LPHW) |
kW
|
27.0
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
0
|
Via LPHW @ 80°C |
kW
|
0
|
Max. available (Mode A + LPHW) |
kW
|
0
|
Refrigerant |
|
R407C
|
Gas weight/CO2 equivalent |
kg/t
|
2.7/4.79
|
Nominal power consumed |
kW
|
3.6
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AA denotes heat recovery to air and optional LPHW heater for air only
|
Specifications | Units | AW 1500 |
---|---|---|
Air flow |
m³/h
|
4,300
|
External available static pressure |
Pa
|
350
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
10.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
13.2
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
14.0
|
Via standard LPHW @ 80°C |
kW
|
28.0
|
Max. available (Mode B + standard LPHW) |
kW
|
36.0
|
Via upgraded LPHW @ 55°C |
kW
|
23.8
|
Max. available (Mode B + upgraded LPHW) |
kW
|
36.8
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
12.5
|
Via LPHW @ 80°C |
kW
|
40.0
|
Max. available (Mode A + LPHW) |
kW
|
52.5
|
Refrigerant |
|
R407C
|
Gas weight/CO2 equivalent |
kg/t
|
3.0/5.32
|
Nominal power consumed |
kW
|
4.7
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AW denotes heat recovery to air/water and LPHW heaters for air/water
|
Specifications | Units | AA 1500 |
---|---|---|
Air flow |
m³/h
|
4,300
|
External available static pressure |
Pa
|
350
|
Fresh air flow (option) |
m³/h
|
0-900
|
External available static pressure |
Pa
|
100
|
Dehumidification @ 30°C/60% RH |
l/h
|
10.5
|
Dehumidification @ 30°C/70% RH |
l/h
|
13.2
|
Heat to air | ||
Net via heat pump (Mode B) |
kW
|
14.0
|
Via standard LPHW @ 80°C |
kW
|
28.0
|
Max. available (Mode B + standard LPHW) |
kW
|
36.0
|
Via upgraded LPHW @ 55°C |
kW
|
23.8
|
Max. available (Mode B + upgraded LPHW) |
kW
|
36.8
|
Heat to water | ||
Net via heat pump (Mode A) |
kW
|
0
|
Via LPHW @ 80°C |
kW
|
0
|
Max. available (Mode A + LPHW) |
kW
|
0
|
Refrigerant |
|
R407C
|
Gas weight/CO2 equivalent |
kg/t
|
2.65/4.70
|
Nominal power consumed |
kW
|
4.7
|
Product size |
|
For sizing options please contact dealer
|
Abbrieviations |
|
AA denotes heat recovery to air and optional LPHW heater for air only
|
Get in touch and we will connect you with the right office or dealer.
The direct route to spare parts for your equipment.
Contact us for help in finding the right service professional near you.
Discover how humidity control is critical to effective data storage
Gain valuable insight into what you need to select the right size dehumidifier for your pool.
Complete your details below and the right person from our expert team will get back to you.
For service and spare parts enquiries please include serial number and product type in the Message field.
Thank you for your enquiry. We will be in touch with you as soon as possible.