Finding the ideal balance of air quality, climate control and cost-saving
- Home
- Products
- Air handling units
- Calorex Delta series – swimming pool air handling units
Calorex Delta series – swimming pool air handling units
The sophisticated Delta air handling units incorporate hybrid heat pump and fresh air dehumidification technology. With dynamic heat recovery to swimming pool water and air using a heat pump, a Delta solution is the ultimate choice for a commercial or public indoor swimming pool.
Key features
-
Dynamic heat pump heat recovery to pool and air
-
Self-regulating fresh air control with heat recovery
-
Automatic control of exhaust air volume to match pool usage
-
Free-cooling (Delta 1-2)
-
Free-cooling and heat pump air cooling (Delta 4-16)
-
Integral LPHW heat exchangers for pool and air
-
Controllable rpm EC/inverter fans in all models
-
PLC control with 5.7" touchscreen user interface
-
Remote monitoring/control
-
The minimum security update period for Delta products is zero months
Remote monitoring/control
-
Screen mirroring to Android/iOS mobile devices using third-party app
-
Screen mirroring to web browser with ActiveX
-
BMS interfaces for Modbus, BACnet IP and BACnet MS/TP
-
Wired remote control interfaces
Options
-
Delta 2-6 single or three phase
-
Delta 8-16 three phase only
-
Upgraded LPHW heat exchanger for air heating
-
Left-hand or right-hand orientation (Delta 4-16)
-
Top, side or bottom supply fan outlet
-
Front or rear supply fan outlet (Delta 14-16)
-
Rear exhaust and fresh air connections (Delta 14-16)
-
Connection for RCU (Delta 16)
Product specifications
Specifications | Units | DT 2 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
2,600
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
130-1,300
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
10.9
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
4.9
|
Via standard LPHW @ 80°C |
kW
|
22
|
Via upgraded LPHW @ 55°C |
kW
|
19
|
Total Mode B + standard LPHW |
kW
|
26.9
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
5.5
|
Via LPHW @ 80°C |
kW
|
23
|
Via LPHW @ 55°C |
kW
|
11
|
Total Mode A + LPHW |
kW
|
28.5
|
Cooling duty | ||
Total |
kW
|
0
|
Sensible |
kW
|
0
|
Nominal power consumed |
kW
|
2.9
|
R407c gas weight/CO2 equivalent |
kg/t
|
3.0/5.32
|
Width |
mm
|
1,740
|
Depth |
mm
|
654
|
Height |
mm
|
1,685
|
Weight |
kg
|
310
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 4 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
3,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
150-1,500
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
12.5
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
5.1
|
Via standard LPHW @ 80°C |
kW
|
25
|
Via upgraded LPHW @ 55°C |
kW
|
21
|
Total Mode B + standard LPHW |
kW
|
30.1
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
5.8
|
Via LPHW @ 80°C |
kW
|
33
|
Via LPHW @ 55°C |
kW
|
16
|
Total Mode A + LPHW |
kW
|
38.8
|
Cooling duty | ||
Total |
kW
|
-4.2
|
Sensible |
kW
|
-2.9
|
Nominal power consumed |
kW
|
2.9
|
R407c gas weight/CO2 equivalent |
kg/t
|
6.0/10.64
|
Width |
mm
|
1,840
|
Depth |
mm
|
704
|
Height |
mm
|
1,970
|
Weight |
kg
|
350
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 6 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
4,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
200-2,000
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
16.6
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
6.6
|
Via standard LPHW @ 80°C |
kW
|
30
|
Via upgraded LPHW @ 55°C |
kW
|
26
|
Total Mode B + standard LPHW |
kW
|
36.6
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
8.0
|
Via LPHW @ 80°C |
kW
|
33
|
Via LPHW @ 55°C |
kW
|
16
|
Total Mode A + LPHW |
kW
|
41.0
|
Cooling duty | ||
Total |
kW
|
-5.5
|
Sensible |
kW
|
-3.9
|
Nominal power consumed |
kW
|
3.4
|
R407c gas weight/CO2 equivalent |
kg/t
|
7.8/13.84
|
Width |
mm
|
1,840
|
Depth |
mm
|
704
|
Height |
mm
|
1,970
|
Weight |
kg
|
360
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 8 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
5,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
250-2,500
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
20.8
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
8.0
|
Via standard LPHW @ 80°C |
kW
|
35
|
Via upgraded LPHW @ 55°C |
kW
|
30
|
Total Mode B + standard LPHW |
kW
|
43.0
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
10.0
|
Via LPHW @ 80°C |
kW
|
33
|
Via LPHW @ 55°C |
kW
|
16
|
Total Mode A + LPHW |
kW
|
43.0
|
Cooling duty | ||
Total |
kW
|
-6.7
|
Sensible |
kW
|
-4.7
|
Nominal power consumed |
kW
|
4.4
|
R407c gas weight/CO2 equivalent |
kg/t
|
7.8/13.84
|
Width |
mm
|
1,840
|
Depth |
mm
|
704
|
Height |
mm
|
1,970
|
Weight |
kg
|
370
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 10 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
6,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
300-3,000
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
25.0
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
10.0
|
Via standard LPHW @ 80°C |
kW
|
38
|
Via upgraded LPHW @ 55°C |
kW
|
32
|
Total Mode B + standard LPHW |
kW
|
48.0
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
12.5
|
Via LPHW @ 80°C |
kW
|
40
|
Via LPHW @ 55°C |
kW
|
20
|
Total Mode A + LPHW |
kW
|
52.5
|
Cooling duty | ||
Total |
kW
|
-8.4
|
Sensible |
kW
|
-5.9
|
Nominal power consumed |
kW
|
5.9
|
R407c gas weight/CO2 equivalent |
kg/t
|
9.0/15.97
|
Width |
mm
|
1,840
|
Depth |
mm
|
854
|
Height |
mm
|
1,970
|
Weight |
kg
|
410
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 12 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
7,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
350-3,500
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
29.2
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
12.1
|
Via standard LPHW @ 80°C |
kW
|
42
|
Via upgraded LPHW @ 55°C |
kW
|
36
|
Total Mode B + standard LPHW |
kW
|
54.1
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
15.0
|
Via LPHW @ 80°C |
kW
|
40
|
Via LPHW @ 55°C |
kW
|
20
|
Total Mode A + LPHW |
kW
|
55.0
|
Cooling duty | ||
Total |
kW
|
-10.1
|
Sensible |
kW
|
-7.1
|
Nominal power consumed |
kW
|
7.4
|
R407c gas weight/CO2 equivalent |
kg/t
|
8.0/14.19
|
Width |
mm
|
1,840
|
Depth |
mm
|
854
|
Height |
mm
|
1,970
|
Weight |
kg
|
460
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 14 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
10,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
670-6,700
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
56.5
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
30.0
|
Via standard LPHW @ 80°C |
kW
|
85
|
Via upgraded LPHW @ 55°C |
kW
|
72
|
Total Mode B + standard LPHW |
kW
|
115.0
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
35.0
|
Via LPHW @ 80°C |
kW
|
65
|
Via LPHW @ 55°C |
kW
|
32
|
Total Mode A + LPHW |
kW
|
100.0
|
Cooling duty | ||
Total |
kW
|
-23.0
|
Sensible |
kW
|
-13.0
|
Nominal power consumed |
kW
|
12.3
|
R407c gas weight/CO2 equivalent |
kg/t
|
21.5/38.14
|
Width |
mm
|
2,860
|
Depth |
mm
|
1,126
|
Height |
mm
|
2,120
|
Weight |
kg
|
954
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Specifications | Units | DT 16 |
---|---|---|
Nominal recirculation air flow |
m³/h
|
12,000
|
Exhaust/fresh air flow (stepped control) |
m³/h
|
850-8,000
|
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air |
l/h
|
62.4
|
Heat to air | ||
Via heat pump (Mode B) |
kW
|
35.0
|
Via standard LPHW @ 80°C |
kW
|
90
|
Via upgraded LPHW @ 55°C |
kW
|
77
|
Total Mode B + standard LPHW |
kW
|
125.0
|
Heat to pool water | ||
Via heat pump (Mode A) |
kW
|
43.0
|
Via LPHW @ 80°C |
kW
|
65
|
Via LPHW @ 55°C |
kW
|
32
|
Total Mode A + LPHW |
kW
|
108.0
|
Cooling duty | ||
Total |
kW
|
-28.0
|
Sensible |
kW
|
-15.0
|
Nominal power consumed |
kW
|
17.0
|
R407c gas weight/CO2 equivalent |
kg/t
|
21.5/38.14
|
Width |
mm
|
2,860
|
Depth |
mm
|
1,126
|
Height |
mm
|
2,120
|
Weight |
kg
|
1,020
|
Nominal recirculation air flow
Exhaust/fresh air flow (stepped control)
Total dehumidification @ 28°C/60% RH by heat pump and maximum fresh air
Heat to air
Via heat pump (Mode B)
Via standard LPHW @ 80°C
Via upgraded LPHW @ 55°C
Total Mode B + standard LPHW
Heat to pool water
Via heat pump (Mode A)
Via LPHW @ 80°C
Via LPHW @ 55°C
Total Mode A + LPHW
Cooling duty
Total
Sensible
Nominal power consumed
R407c gas weight/CO2 equivalent
Width
Depth
Height
Weight
Suitable for
Useful downloads
Looking to buy?
Get in touch and we will connect you with the right office or dealer.
Looking for spares?
The direct route to spare parts for your equipment.
Looking for servicing?
Contact us for help in finding the right service professional near you.
Related products
Featured insights
How we can adapt our DanX units to meet our customers’ unique requirements.
Read this case study on how we transformed the efficiency of an old DanX unit on a modest budget.
Complete your details below and the right person from our expert team will get back to you.
For service and spare parts enquiries please include serial number and product type in the Message field.
Thank you for your enquiry. We will be in touch with you as soon as possible.