Dantherm VA-M40 MKII – tent heater
Tent heaters
The warm air heater VA-M40 MKII is a mobile 38kW unit primarily developed to provide heating in temporary or transportable buildings or tents.
The VA-M40 MKII operates according to the indirect fired principle meaning that the supply airstream is heated separately from the combustion chamber. This way, the tent is heated with clean air free from combustion products or fumes.
View all of our tent heaters or search for an indirect oil fired, indirect fuel fired or other type of commercial heater to meet your required applications.
![]()
Dantherm VA-M40MKII – tent heater
| ![]()
Dantherm VA-M40 MKII field hospital installation
|
![]()
Installing a VA-M40 MKII tent heater
| ![]()
VA-M tent heater video
|
![]()
Dantherm energy saving heat exchanger ventilation unit for deployable field camps
|
Key features
- Can operate at temperatures down to -40°C
- Creates a comfortable working environment
- Equipment and transportation such as helicopters stay warm and ready for use, reducing wear and tear and ensuring quicker response times
- Reliable and virtually maintenance free
- Easy to transport, even over ice and snow
- Can be set up by one person without the use of tools, and is easy to operate
- Developed in close collaboration with the armed forces of NATO countries
- Chosen as the NATO standard, conforming to all NATO requirements and norms
- All units are allocated NATO stock numbers (NSN)
- Ideal for open air operation with ducted supply and return air
- Adjustable fresh-air intake
- The efficient multi-liquid burner accepts almost all diesel fuels
Product specifications
Specifications | Units | VA-M40 MKII |
---|---|---|
Registered NSN number | - | Yes |
Operating temperature range | °C | -40 – +30 |
Heat output | kW | 38 |
Air flow | m³/h | 2,200 |
Sound level @ 1.5m | dB(A) | 60 |
Protection class | IPX4 | |
Max. fuel consumption | l/h | 3.6 |
Power supply | V/Hz | 230/1ph/50 |
Max. power consumption | W | 1,055 |
Air discharge temperature | °C | 80 |
Flex duct connection | Ømm | 225 |
Product size (h x l x w) | mm | 890 x 1400 x 700 |
Weight | kg | 129 |
Product specifications (US)
Specifications | Units | VA-M40MKII |
---|---|---|
Registered NSN number | Yes | |
Operating temperature range | °F | -40 to +86 |
Heat output | BTU | 129,600 |
Air flow | SCFM | 1,371 |
Sound level @5 feet | dB(A) | 60 |
Protection class | NEMA | 3S |
Max. fuel consumption | lbs/h | 7.7 |
Power supply | V/Hz | 230/1ph/50 |
Max. power consumption | W | 1055 |
Air discharge temperature | °F | 176 |
Flex duct connection | Øin | 8.6 |
Product size (h x l x w) | in | 35 x 55.1 x 27.6 |
Weight | lbs | 284 |
Suitable for:
- Camps and field hospitals
- Events and festivals
- Military and aerospace