Calorex I-PAC 8-12-16-22 – inverter swimming pool heat pumps
Small inverter heat pumps
Inverter technology allows for efficient control of the pool temperature, and the I-PAC only uses what energy is needed when it is required. High efficiency with modulating step-less inverter compressor giving an average COP of 9.7.
View our range of swimming pool heat pumps today and find large pool heat pumps and small pool heat pumps suitable for all domestic and commercial purposes on any scale.
![]()
DANTHERM Calorex I PAC 8 12 16 22 ALX heatpump web main
| ![]()
Introduction to the I-PAC inverter heat pumps
|
![]()
Calorex I PAC V PAC installation animation
| ![]()
DANTHERM Calorex I PAC 16 ALX heatpump web
|
![]()
Calorex I-PAC+ 12-16-22-28 – inverter swimming pool heat pump
| ![]()
Calorex I PAC 12 – inverter swimming pool heat pump
|
![]()
Calorex I PAC 16 ALX – inverter swimming pool heat pump side view
| ![]()
DANTHERM Calorex I PAC Family heatpump web
|
![]()
Calorex I PAC controller
| ![]()
Pool Therm App home screen
|
![]()
Calorex inverter temperature control graph
| ![]()
Calorex heating method efficiency chart
|
Key features
- 2 x more efficient than on/off heat pumps
- Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
- Inverter heat pump
- Power ratings from 9.5 to 25kW
- 9-11 dB(A) sound reduction compared to an equivalent on/off heat pump, with ‘Whisper Mode’
- Operates in air temperatures of -5°C to +43°C
- Integrated controller with a touchscreen user interface
- Function settings for heating, cooling or heat/cool
- Soft start-up
- Aluminium alloy
- Built-in Wi-Fi module
- PoolTherm App is available on Android and iOS
- Winter protection cover included
- The minimum security update period for I-PAC or I-PAC+ products is zero months
- The minimum security update period for the PoolTherm App aligns with warranty period of the connected product (5 years from date of sale of the connected I-PAC or I-PAC+ heat pump)
New refrigerant gas
- Has a low GWP (675)
- Zero ozone depleting potential (ODP)
- Is F-gas phase-down compliant
- Requires less refrigerant volume per kW
- Is easier to reuse and recycle
Product specifications
Specifications | Units | I-PAC 8ALX |
---|---|---|
Air temperature range | °C | -5-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 9.5 |
COP range | 13.2-5.4 | |
Average COP at 50% speed | 8.9 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 7.0 |
COP range | 6.9-4.2 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 4.5 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 3.9 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.3-1.79 |
Maximum input current | A | 9.5 |
Water flow | m³/h | 3.0-5.0 |
Water connection | "/mm | 1½/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 0.6/0.41 |
Sound level @ 10m | dB(A) | 19.6-31.5 |
Product size (w x d x h) | mm | 864 x 359 x 648 |
Weight | kg | 47 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC 12ALX |
---|---|---|
Air temperature range | °C | -5-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 13 |
COP range | 13.5-5.6 | |
Average COP at 50% speed | 9.7 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 9.5 |
COP range | 7.0-4.0 | |
Average COP at 50% speed | 6.1 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 5.6 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 5.2 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.40-2.38 |
Maximum input current | A | 12.5 |
Water flow | m³/h | 4.0-6.0 |
Water connection | "/mm | 1½/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 0.9/0.61 |
Sound level @ 10m | dB(A) | 21.9-32.0 |
Product size (w x d x h) | mm | 864 x 359 x 648 |
Weight | kg | 49 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC 16ALX |
---|---|---|
Air temperature range | °C | -5-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 20 |
COP range | 13.5-5.7 | |
Average COP at 50% speed | 9.3 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 13.5 |
COP range | 7.0-4.2 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 7.9 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 7.4 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.57-3.21 |
Maximum input current | A | 19.5 |
Water flow | m³/h | 7.0-10.0 |
Water connection | "/mm | 1½/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 1.1/0.74 |
Sound level @ 10m | dB(A) | 24.3-36.1 |
Product size (w x d x h) | mm | 954 x 359 x748 |
Weight | kg | 68 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC 22ALX |
---|---|---|
Air temperature range | °C | -5-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 25 |
COP range | 13.8-5.8 | |
Average COP at 50% speed | 9.6 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 17 |
COP range | 7.2-4.0 | |
Average COP at 50% speed | 6.4 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 9.9 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 9.4 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.69-4.25 |
Maximum input current | A | 20 |
Water flow | m³/h | 10.0-12.0 |
Water connection | "/mm | 1½/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 2.0/1.35 |
Sound level @ 10m | dB(A) | 24.9-36.7 |
Product size (w x d x h) | mm | 1084 x 429 x 948 |
Weight | kg | 90 |
Included in the box | Rubber feet, drainage pipe, water union |
Suitable for:
- Leisure and recreation
- Swimming pools