Calorex I-PAC+ 12-16-22-28 – inverter swimming pool heat pumps
Small inverter heat pumps
Inverter technology allows for efficient control of the pool temperature, and the I-PAC+ only uses what energy is needed when it is required. High efficiency with modulating step-less inverter compressor giving an average COP >10.1.
View our range of swimming pool heat pumps today and find large pool heat pumps and small pool heat pumps suitable for all domestic and commercial purposes on any scale.
![]()
Calorex I-PAC+ 12-16-22-28 – inverter swimming pool heat pump
| ![]()
Introduction to the I-PAC inverter heat pumps
|
![]()
Calorex I PAC V PAC installation animation
| ![]()
Calorex I PAC 22 – inverter swimming pool heat pumps
|
![]()
Calorex I PAC 22 – inverter swimming pool heat pumps
| ![]()
DANTHERM Calorex I PAC Family heatpump web
|
![]()
Calorex I PAC controller
| ![]()
Pool Therm App home screen
|
![]()
Calorex inverter temperature control graph
| ![]()
Calorex heating method efficiency chart
|
Key features
- Average COP >10.1 = 2 x more efficient than on/off heat pumps
- Eco-friendly refrigerant R32 = 675 GWP, (Global Warming Potential)
- Inverter heat pump
- Power ratings from 15 to 36kW
- 9-11 dB(A) sound reduction compared to an equivalent on/off heat pump, with ‘Whisper Mode’
- Operates in air temperatures of -10°C to +43°C
- Integrated controller with a touchscreen user interface
- Function settings for heating, cooling or heat/cool
- Soft start-up
- Aluminium alloy
- Built-in Wi-Fi module
- PoolTherm App is available on Android and iOS
- Winter protection cover included
- The minimum security update period for I-PAC or I-PAC+ products is zero months
- The minimum security update period for the PoolTherm App aligns with warranty period of the connected product (5 years from date of sale of the connected I-PAC or I-PAC+ heat pump)
New refrigerant gas
- Has a low GWP (675)
- Zero ozone depleting potential (ODP)
- Is F-gas phase-down compliant
- Requires less refrigerant volume per kW
- Is easier to reuse and recycle
Benefits
- All year heating for outdoor and indoor pools
- Can operate down to -10°C ambient air temperature
- High heating performance at lower temperatures – ideal for quick pool heat up at the start of the season
- Pool heating at altitude
- Higher cooling capacity
- Most efficient models – highest COP
- PoolTherm App is available on Android and iOS
Product specifications
Specifications | Units | I-PAC+ 12ALY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 15 |
COP range | 15.0-6.6 | |
Average COP at 50% speed | 10.6 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 10.5 |
COP range | 7.7-4.6 | |
Average COP at 50% speed | 6.4 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 6.8 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 3.2 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 6.7 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.27-2.28 |
Maximum input current | A | 13.5 |
Water flow | m³/h | 5.0-7.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 0.9/0.61 |
Sound level @ 10m | dB(A) | 20.8-34.5 |
Product size (w x d x h) | mm | 954 x 359 x 648 |
Weight | kg | 52 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC+ 16ALY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 21 |
COP range | 14.8-6.4 | |
Average COP at 50% speed | 10.3 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 14.5 |
COP range | 7.1-4.6 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 8.9 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 4.2 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 9.5 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.41-3.15 |
Maximum input current | A | 17 |
Water flow | m³/h | 8.0-10.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 1.2/0.81 |
Sound level @ 10m | dB(A) | 20.4-33.7 |
Product size (w x d x h) | mm | 954 x 429 x 755 |
Weight | kg | 68 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC+ 16BLY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 21 |
COP range | 14.8-6.4 | |
Average COP at 50% speed | 10.3 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 14.5 |
COP range | 7.5-4.6 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 8.9 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 4.2 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 9.5 |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kW | 0.41-3.15 |
Maximum input current | A | 5.8 |
Water flow | m³/h | 8.0-10.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 1.2/0.81 |
Sound level @ 10m | dB(A) | 20.4-33.7 |
Product size (w x d x h) | mm | 954 x 429 x 755 |
Weight | kg | 68 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC+ 22ALY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 27.5 |
COP range | 15.0-6.8 | |
Average COP at 50% speed | 10.3 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 18 |
COP range | 7.5-4.6 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 11.4 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 5.2 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 11.9 |
Power supply | V/Hz | 230/1ph/50 |
Rated input power | kW | 0.48-3.91 |
Maximum input current | A | 20 |
Water flow | m³/h | 10.0-12.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 2.0/1.35 |
Sound level @ 10m | dB(A) | 23.0-34.4 |
Product size (w x d x h) | mm | 1084 x 429 x 948 |
Weight | kg | 90 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC+ 22BLY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 27.5 |
COP range | 15.0-6.5 | |
Average COP at 50% speed | 10.3 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 18 |
COP range | 7.5-4.6 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 11.4 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 5.2 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 11.9 |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kW | 0.48-3.91 |
Maximum input current | A | 7.0 |
Water flow | m³/h | 10.0-12.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 2.0/1.35 |
Sound level @ 10m | dB(A) | 23.0-34.4 |
Product size (w x d x h) | mm | 1084 x 429 x 948 |
Weight | kg | 93 |
Included in the box | Rubber feet, drainage pipe, water union |
Specifications | Units | I-PAC+ 28BLY |
---|---|---|
Air temperature range | °C | -10-43 |
Water temperature range | °C | 12-40 |
Performance – air 27°C 80% RH, water 27°C | ||
Heating capacity | kW | 36 |
COP range | 14.8-6.0 | |
Average COP at 50% speed | 10.2 | |
Performance – air 15°C 70% RH, water 26°C | ||
Heating capacity | kW | 23.9 |
COP range | 7.5-4.6 | |
Average COP at 50% speed | 6.3 | |
Performance – air 5°C 70% RH, water 10°C | ||
Heating capacity | kW | 16.8 |
Performance – air -10°C 70% RH, water 23°C | ||
Heating capacity | kW | 7.7 |
Performance – air 35°C 80% RH, water 28°C | ||
Cooling capacity | kW | 16 |
Power supply | V/Hz | 400/3ph/50 |
Rated input power | kW | 0.64-5.20 |
Maximum input current | A | 9.5 |
Water flow | m³/h | 12.0-18.0 |
Water connection | "/mm | 1½"/50 |
Compressor | Inverter | |
Condenser | Titanium | |
R32 gas weight/CO2 equivalent | kg/t | 2.7/1.82 |
Sound level @ 10m | dB(A) | 22.1-34.2 |
Product size (w x d x h) | mm | 1154 x 539 x 948 |
Weight | kg | 120 |
Included in the box | Rubber feet, drainage pipe, water union |
Suitable for: