Simplify Sensor Probe – relative humidity/temperature
Remote monitoring control system
Simplify Sensor Probe – Relative Humidity/Temperature (RH/TEMP) is part of the Simplify solution.
The probe measures relative humidity and temperature with a unique precision of +/- 2.0 % in the range from 0-100% RH and +/- 0.2°C deviation on the temperature measurements.
The opening of the probe, from where the probe measures is IP67 protected (the probe is dust tight and it is submersible in water <1m up to 30 mins) giving ideal protection in harsh environments.
The diameter of the probe is only 8mm, minimising the size of the repair work required post-drying. The probe comes with different lengths of cable – 24cm, 300cm, and 2000cm.
![]()
Simplify Sensor Probe – Relative Humidity/Temperature
| ![]()
How to program Simplify Climate Solutions
|
![]()
How to insert batteries into Sensor Boxes
| ![]()
How to end and archive a job
|
Applications
- Restoration processes after water damages
- Monitoring buildings in the construction phase
- Monitoring buildings throughout their lifetime
- Indoor air climate analysis
- The probe can be used in air and materials such as wood, concrete where RH% measuring is required
Key features
- High accuracy
- Slim design Ø8mm
- IP67
- Rugged design
- Combined humidity and temperature measurement
Installation
- Simplify Sensor Probe - Relative Humidity/Temperature is part of the Simplify solution. It is connected to the Simplify Sensor Box to enable measuring temperature and humidity data
- The Simplify Sensor Box is automatically powered ON, when probe is connected
- The probe is connected to the Simplify Sensor Box via a mini DIN connector
- The probe can be used in free air or inserted into materials where relative humidity and temperature must be measured
Product specifications
Specifications | Units | Simplify Sensor Probe – Relative Humidity/Temperature |
---|---|---|
Voltage | VDC | 3.3 |
Current | mA | 1.5 |
Power | mW | 5 |
RH range | %RH | 0 -100 |
Tolerance RH | %RH | +/- 2 |
Resolution RH | %RH | 0.01 |
Temperature range | °C | -40 - +100 |
Tolerance Temp | °C | +/- 0.2 |
Resolution Temp | °C | 0.01 |
Protection class (Probe tip) | IP67 |
Suitable for
- Agriculture
- Camps and field hospitals
- Commercial buildings
- Construction
- Data centers and telecoms
- Military and aerospace
- Rental companies
- Water damage restoration